TREATED FOR OUTDOOR

  • NF Exterieur CTB-X

  • Class 4 or class 3

  • Sanded faces

 

Rolpin TRHT, TA and TA Eligia are maritime pine multiplex plywood from France intended to wood-framed houses, chalets, sheds, exterior cladding, fencing.

 

Caractéristiques du produit

Face Face fermée, sans noeud et avec pastilles bois (maxi 6/m²). Réparations mastic occasionnelles
Back Face fermée, avec noeuds sains et pastilles bois. Réparations mastic occasionnelles
Finish Les 2 faces sont poncées
Dimensions TRHT : 2500 x 1250 mm (please contact us for other formats)
TA : 2500 x 1250 mm (please contact us for other formats)
TA Elegia : 2500 x 1200 mm (please contact us for other formats)
Thickness
TRHT :15 mm
TA : From 15 to 18 mm />
TA Elegia : 15 mm
Packaging
40

Density
560 to 610 kg/m3

Uses
Wood-framed houses, chalets, sheds, exterior cladding, fencing

Bond


According to EN 314-2 standard: bonding class 3 “exterior applications» water and weather resistant.
Phenolic glue.

Options


Cutting, machining available upon request.

Structural use in construction / TA Elegia and TRHT = Non structural construction applications.

System 2 + Certificate of conformity according to EN 13986 + A1

Exterior conditions


According to EN 636 + A1 (structural use).French NF exterior CTBX quality mark and the German BFU 100 DIN 68705 part 3 certified.

Formaldehyde emission


E1 classification according to EN 717.2 standards. Formaldehyde emission measurements reveal a clearance of 0.02 mg/L air using desiccator method ISO 12460-4. This value is 15 times lower than the Japanese F**** standard requirements, the most stringent in the world (0.3 mg/l) according to JIS A 1460 standard.

Fire reaction classification


According to EN 13501-1 +A1
Thickness > 9 mm : Euroclass D-s2, d0

Marking CE
n° 380 – CPD – 011 - EN 13986 + A1

ctbx
pefc
a+
fabriquéfrance
fnpa
ce

Storage


It is best to store the units in a dry place, preferably flat and level on dry supports keeping them off the soil. Spacing between rafters is to adapt to the thickness and the nature of the stored panels. During storage in several piles, align the supports with the long side. On a construction site, plan for shelter or for covering for the panels that is simultaneously water repellent and permeable to water vapor.

Implementation


To comply with current industry, safety, and building codes.

Panel dimensional tolerances are as follows


They are in compliance with standard EN 315 requirements :

  • Length/width dimensional tolerance: ±3.5 mm
  • Straightness of edges and squaring: 1 mm per linear metre
  • Thickness tolerance according to NF EN 315 standards

Other features


Thermal conductivity
Environmental sustainability


Pentachlorophenol levels
Water vapour permeability
Sound absorption


λ = 0,13W/.K
Maritime pine species:
Class 3 - 4 according to EN 350 part 2
< 5 ppm. (PCP)
70 μ wet / 200 μ dry
250 à 500 Hz = 0,10
1000 à 2000 Hz = 0,30

Pour plus de renseignements et consulter caractéristiques mécaniques, téléchargez la fiche technique disponible ci-dessous.